{"id":6215,"date":"2025-05-19T18:04:04","date_gmt":"2025-05-19T10:04:04","guid":{"rendered":"https:\/\/cicserver.com\/liquid-cooling-becoming-essential-as-ai-servers-proliferate\/"},"modified":"2025-05-19T18:04:04","modified_gmt":"2025-05-19T10:04:04","slug":"liquid-cooling-becoming-essential-as-ai-servers-proliferate","status":"publish","type":"post","link":"https:\/\/cicserver.com\/de\/liquid-cooling-becoming-essential-as-ai-servers-proliferate\/","title":{"rendered":"Liquid cooling becoming essential as AI servers proliferate"},"content":{"rendered":"<p><br \/>\n<br \/><img decoding=\"async\" src=\"https:\/\/www.networkworld.com\/wp-content\/uploads\/2025\/05\/3978673-0-44029000-1747648960-shutterstock_2476735433.jpg?quality=50&amp;strip=all\" \/><\/p>\n<div>\n<p>\u201cFacility water loops sometimes have good water quality, sometimes bad,\u201d says My Troung, CTO at <a href=\"https:\/\/zutacore.com\/\">ZutaCore<\/a>, a liquid cooling company. \u201cSometimes you have organics you don\u2019t want to have inside the technical loop.\u201d<\/p>\n<p>So there\u2019s one set of pipes that goes around the data center, collecting the heat from the server racks, and another set of smaller pipes that lives inside individual racks or servers. \u201cThat inner loop is some sort of technical fluid, and the two loops <a href=\"https:\/\/www.networkworld.com\/article\/2108453\/zutacore-launches-liquid-cooling-for-advanced-nvidia-chips.html\">exchange heat across a heat exchanger<\/a>,\u201d says Troung.<\/p>\n<p>The most common approach today, he says, is to use a single-phase liquid \u2014 one that stays in liquid form and never evaporates into a gas \u2014 such as water or propylene glycol. But it\u2019s not the most efficient option.<\/p>\n<p>Evaporation is a great way to dissipate heat. That\u2019s what our bodies do when we sweat. When water goes from a liquid to a gas it\u2019s called a phase change, and it uses up energy and makes everything around it slightly cooler.<\/p>\n<p>Of course, few servers run hot enough to boil water \u2014 but they can boil other liquids. \u201cTwo phase is the most efficient cooling technology,\u201d says Xianming (Simon) Dai, a professor at University of Texas at Dallas.<\/p>\n<p>And it might be here sooner than you think. In a <a href=\"https:\/\/www.nvidia.com\/gtc\/keynote\/\">keynote address<\/a> in March at Nvidia GTC, Nvidia CEO Jensen Huang <a href=\"https:\/\/www.networkworld.com\/article\/3848394\/nvidia-details-its-gpu-cpu-and-system-roadmap-for-the-next-three-years.html\">unveiled the Rubin Ultra NVL576<\/a>, due in the second half of 2027 \u2014 with 600 kilowatts per rack.<\/p>\n<p>\u201cWith the 600 kilowatt racks that Nvidia is announcing, the industry will have to shift very soon from single-phase approaches to two-phase,\u201d says ZutaCore\u2019s Troung.<\/p>\n<p>Another highly-efficient cooling approach is immersion cooling.<\/p>\n<p>According to a <a href=\"https:\/\/www.castrol.com\/en\/global\/corporate\/about-castrol\/newsroom\/castrol-releases-dipping-point-industry-research-report.html\">Castrol survey<\/a> released in March, 90% of 600 data center industry leaders say that they are considering switching to immersion cooling by 2030.<\/p>\n<p>But immersion cooling does have its downsides. According to the survey, 38% of respondents are concerned about the potential for leaks, 31% say that it\u2019s too time-consuming to implement, and 31% worry about maintenance challenges.<\/p>\n<p>Colocation provider <a href=\"https:\/\/www.equinix.com\/\">Equinix<\/a>, which has more than 260 data centers in 72 markets, has liquid cooling already available at 100 of them \u2014 and continues to build new liquid-cooled facilities and retrofit older ones.<\/p>\n<p>But it hasn\u2019t seen much demand for immersion cooling yet, says Phil Read, the company\u2019s senior director of data center services. \u201cIt\u2019s definitely an area we\u2019re monitoring,\u201d he says. \u201cIt could be interesting in the future.\u201d<\/p>\n<p>Today, however, the technology still has some issues. For one thing, there\u2019s the weight, he says. \u201cYou\u2019re basically putting the weight of a small car on a data center floor.\u201d<\/p>\n<p>And then there\u2019s the issue of the kinds of liquids that are used for immersion cooling. \u201cEquinix has a strong sustainability posture and PFAS chemicals are very problematic for us,\u201d he says. \u201cBut we see those used in immersion cooling \u2014 and in two-phase cooling as well.\u201d<\/p>\n<p>It\u2019s not clear yet exactly how the industry will manage the power and cooling requirements of next-generation AI servers. Maybe AI will come up with some suggestions.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>\u201cFacility water loops sometimes have good water quality, sometimes bad,\u201d says My Troung, CTO at ZutaCore, a liquid cooling company. \u201cSometimes you have organics you don\u2019t want to have inside the technical loop.\u201d So there\u2019s one set of pipes that goes around the data center, collecting the heat from the server racks, and another set [&hellip;]<\/p>","protected":false},"author":3,"featured_media":6216,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","footnotes":""},"categories":[1],"tags":[],"class_list":{"0":"post-6215","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-blog"},"_links":{"self":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/posts\/6215","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/comments?post=6215"}],"version-history":[{"count":0,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/posts\/6215\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/media\/6216"}],"wp:attachment":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/media?parent=6215"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/categories?post=6215"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/tags?post=6215"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}