{"id":1941,"date":"2024-09-25T13:50:49","date_gmt":"2024-09-25T05:50:49","guid":{"rendered":"https:\/\/cicserver.com\/?post_type=product&#038;p=1941"},"modified":"2024-09-25T13:50:49","modified_gmt":"2024-09-25T05:50:49","slug":"ws-c6509-e","status":"publish","type":"product","link":"https:\/\/cicserver.com\/de\/produkt-2\/ws-c6509-e\/","title":{"rendered":"WS-C6509-E"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"100%\">\n<h3 align=\"center\"><strong>WS-C6509-E Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>Number of Slots<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">9<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>Supervisor Compatibility<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">Cisco Catalyst 6500 Series Supervisor Engine 32<\/p>\n<p>Cisco Catalyst 6500 Series Supervisor Engine 720-3B<\/p>\n<p>Cisco Catalyst 6500 Series Supervisor Engine 720-3BXL<\/p>\n<p>Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3C<\/p>\n<p>Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3CXL<\/p>\n<p>Cisco Catalyst 6500 Series Supervisor Engine 2T<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>Power Supply Compatibility<\/strong><\/p>\n<p><strong>*\u00a0Indicates EoS Power Supply<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">AC: 2500W*, 3000W, 4000W, 6000W, 8700W<\/p>\n<p>DC: 2500W, 4000W, 6000W<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>Module Compatibility<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">All modules based on the software release in the system<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>With Supervisor Engine 32<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">\u25cf\u00a0\u00a012.2(18)SXF<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>With Supervisor Engine 720<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">\u25cf\u00a0\u00a012.2(14)SX<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>With Supervisor Engine 720-10 GE<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">\u25cf\u00a0\u00a012.2(33)SXH<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>With Supervisor Engine 2T-10 GE<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">\u25cf\u00a0\u00a015.0(1)SY<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>Reliability and Availability<\/strong><\/p>\n<p><strong>Calculated Mean Time Between Failure (MTBF)<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">348,935<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>Inches<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">24.5 x 17.5 x 18.2<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>Centimeters<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">62.2 x 44.5 x 46.0<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>Rack Units (RU)<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">14<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>Chassis Only (lbs)<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">60<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>Fully Configured (lbs)<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">190<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>Input Voltage<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">100 to 240 VAC<\/p>\n<p>-48 to -60 VDC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>Safety<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">UL 60950 Second Edition<\/p>\n<p>CAN\/CSA-C22.2 No. 60950 Second Edition<\/p>\n<p>EN 60950 Second Edition<\/p>\n<p>IEC 60950 Second Edition<\/p>\n<p>AS\/NZS 60950<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>EMC<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">FCC Part 15 (CFR 47) Class A<\/p>\n<p>VCCI Class A<\/p>\n<p>EN55022 Class A<\/p>\n<p>CISPR 22 Class A<\/p>\n<p>CE marking<\/p>\n<p>AS\/NZS 3548 Class A<\/p>\n<p>ETS300 386<\/p>\n<p>EN55024<\/p>\n<p>EN61000-6-1<\/p>\n<p>EN50082-1<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>NEBS\/ETSI<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">GR-1089-Core NEBS Level 3<\/p>\n<p>ETS 300 019 Storage Class 1.1<\/p>\n<p>ETS 300 019 Transportation Class 2.3<\/p>\n<p>ETS 300 019 Stationary Use Class 3.1<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>ATIS Pb free and Energy Efficiency<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">ATIS-0600020.2010 Pb Free circuit packs<\/p>\n<p>ATIS-0600015-2009 General Energy Efficiency Requirements (TEER)<\/p>\n<p>ATIS-0600015.03-2009 Switch and Router Energy Efficiency<\/p>\n<p>ATIS-0600015.01-2009 <a href=\"https:\/\/cicserver.com\/de\/openai-signs-new-4bn-cloud-deal-with-coreweave\/\">Server<\/a> Energy Efficiency<\/p>\n<p>VZ.TPR.9205 Verizon Energy Efficiency Requirements for Telecommunication Equipment (TEEER)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>Operating Temperature<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">32\u00b0F to 104\u00b0F (0 to 40\u00b0C)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>Storage Temperature<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">-4 to 149\u00b0F (-20 to 65\u00b0C)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>Thermal Transition<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">0.5\u00b0C per minute (hot to cold)<\/p>\n<p>0. 33\u00b0C per minute (cold to hot)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>Relative Humidity<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">Ambient (noncondensing) operating: 5% to 90%<\/p>\n<p>Ambient (noncondensing) nonoperating and storage: 5% to 95%<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"26%\"><strong>Operating Altitude<\/strong><\/td>\n<td valign=\"top\" width=\"73%\">Certified for operation: 0 to 6500 ft (0 to 2000 m)<\/p>\n<p>Designed and tested for operation: -200 to 10,000 ft (-60 to 3000 m)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>The 9-slot Cisco Catalyst 6509-E Switch provides high port densities that are ideal for many wiring closet, distribution, and core network as well as data center deployments with exceptional functionality and flexibility. Supervisor engine redundancy and power redundancy supporting deliver the low latency and high scalability network experience to ensure superior reliability for edging or core network. Any two Cisco Catalyst 6500E series Switches with Supervisor Engine 720-3C\/720-3CXL\/S2T-10G\/S2T-10G-XL can be pooled together into a VSS.<\/p>","protected":false},"featured_media":1944,"comment_status":"open","ping_status":"closed","template":"","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":""},"product_cat":[29,30],"product_tag":[47],"class_list":{"0":"post-1941","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco","7":"product_cat-networking","8":"product_tag-catalyst-6500","10":"first","11":"instock","12":"shipping-taxable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product\/1941","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/comments?post=1941"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/media\/1944"}],"wp:attachment":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/media?parent=1941"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product_cat?post=1941"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product_tag?post=1941"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}