{"id":2586,"date":"2024-09-27T20:10:37","date_gmt":"2024-09-27T12:10:37","guid":{"rendered":"https:\/\/cicserver.com\/?post_type=product&#038;p=2586"},"modified":"2024-09-27T20:10:37","modified_gmt":"2024-09-27T12:10:37","slug":"n3k-c3064tq-10gt","status":"publish","type":"product","link":"https:\/\/cicserver.com\/de\/produkt-2\/n3k-c3064tq-10gt\/","title":{"rendered":"N3K-C3064TQ-10GT"},"content":{"rendered":"<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td colspan=\"3\" valign=\"top\">\n<h3 align=\"center\"><strong>N3K-C3064TQ-10GT Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Physical<\/strong><\/td>\n<td colspan=\"2\" valign=\"top\">\u25cf\u00a0\u00a01RU fixed form factor<\/p>\n<p>\u25cf\u00a0Cisco Nexus 3064-T: 64 x 10 Gigabit Ethernet ports (48 10GBASE-T and 4 QSFP+)<\/p>\n<p>\u25e6\u00a0\u00a0 48 RJ-45 ports support 100 Mbps and 1 and 10 Gigabit Ethernet<\/p>\n<p>\u25e6\u00a0\u00a0 4 QSFP ports support 4 x 10 Gigabit Ethernet or 40 Gigabit Ethernet each<\/p>\n<p>\u25cf\u00a0\u00a02 redundant power supplies<\/p>\n<p>\u25cf\u00a0\u00a01fan tray with redundant fans<\/p>\n<p>\u25cf\u00a0\u00a01 I\/O module with management, console, and USB flash memory ports<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Performance<\/strong><\/td>\n<td colspan=\"2\" valign=\"top\">\u25cf\u00a0\u00a01.28-Tbps switching capacity<\/p>\n<p>\u25cf\u00a0\u00a0Forwarding rate of 950 mpps<\/p>\n<p>\u25cf\u00a0\u00a0Line-rate traffic throughput (both Layer 2 and 3) on all ports<\/p>\n<p>\u25cf\u00a0\u00a0Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"9\" valign=\"top\"><strong>Hardware tables and scalability<\/strong><\/td>\n<td valign=\"top\">MAC addresses<\/td>\n<td valign=\"top\">128,000<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of VLANS<\/td>\n<td valign=\"top\">4096<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Spanning-tree instances<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Rapid Spanning Tree Protocol (RSTP): 512<\/p>\n<p>\u25cf\u00a0\u00a0Multiple Spanning Tree (MST) Protocol: 64<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">ACL entries<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a02000 ingress<\/p>\n<p>\u25cf\u00a0\u00a01000 egress<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Routing table<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a016,000 prefixes and 16,000 host entries<\/p>\n<p>\u25cf\u00a0\u00a08000 multicast routes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of EtherChannels<\/td>\n<td valign=\"top\">64 (with vPC)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of ports per EtherChannel<\/td>\n<td valign=\"top\">32<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Buffers<\/td>\n<td valign=\"top\">9 MB shared<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Boot flash memory<\/td>\n<td valign=\"top\">2 GB<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\" valign=\"top\"><strong>Power<\/strong><\/td>\n<td valign=\"top\">Number of power supplies<\/td>\n<td valign=\"top\">2<\/p>\n<p>\u25cf\u00a0\u00a0Cisco 3064-T and 3064-32T: Redundant for AC power<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Power supply types<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0AC (forward and reversed airflow)<\/p>\n<p>\u25cf\u00a0\u00a0DC (forward and reversed airflow)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Typical operating power<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0CiscoNexus 3064-T<\/p>\n<p>\u25e6\u00a0\u00a0 362W (48p with 3m cables; 4 SR4 at 100% load)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">AC PSUs<\/p>\n<p>\u25cf\u00a0\u00a0Input voltage<\/p>\n<p>\u25cf\u00a0\u00a0Frequency<\/p>\n<p>\u25cf\u00a0\u00a0Efficiency<\/td>\n<td valign=\"top\">&nbsp;<\/p>\n<p>\u25cf\u00a0\u00a0100 to 240 VAC<\/p>\n<p>\u25cf\u00a0\u00a050 to 60 Hz<\/p>\n<p>\u25cf\u00a0\u00a089 to 91% at 220V<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">DC PSUs<\/p>\n<p>\u25cf\u00a0\u00a0Input voltage<\/p>\n<p>\u25cf\u00a0\u00a0Maximum current<\/p>\n<p>\u25cf\u00a0\u00a0Efficiency<\/td>\n<td valign=\"top\">&nbsp;<\/p>\n<p>\u25cf\u00a0\u00a0-40 to -72 VDC<\/p>\n<p>\u25cf\u00a0\u00a033A<\/p>\n<p>\u25cf\u00a0\u00a085 to 88%<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Typical heat dissipation<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Cisco Nexus 3064-T<\/p>\n<p>\u25e6\u00a0\u00a0 1235 BTU\/hr (48p with 3m cables; 4 SR4 at 100% load)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Maximum heat dissipation<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Cisco Nexus 3064-T: 1553 BTU\/hr<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Cooling<\/strong><\/td>\n<td colspan=\"2\" valign=\"top\">Forward and reversed airflow schemes:<\/p>\n<p>\u25cf\u00a0\u00a0Forward airflow: Port-side exhaust (air enters through fan-tray and power supplies and exits through ports)<\/p>\n<p>\u25cf\u00a0\u00a0Reversed airflow: Port-side intake (air enters through ports and exits through fan-tray and power supplies)<\/p>\n<p>Single fan tray with redundant fans<\/p>\n<p>Hot swappable (must swap within 1 min)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Sound<\/strong><\/td>\n<td valign=\"top\">Measured sound power (maximum)<\/p>\n<p>\u25cf\u00a0\u00a0Fan speed: 40% duty cycle<\/p>\n<p>\u25cf\u00a0\u00a0Fan speed: 60% duty cycle<\/p>\n<p>\u25cf\u00a0\u00a0Fan speed: 100% duty cycle<\/td>\n<td valign=\"top\">&nbsp;<\/p>\n<p>\u25cf\u00a0\u00a059.7 dBA<\/p>\n<p>\u25cf\u00a0\u00a066.4 dBA<\/p>\n<p>\u25cf\u00a0\u00a071.0 dBA<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\" valign=\"top\"><strong>Environment<\/strong><\/td>\n<td valign=\"top\">Dimensions (height x width x depth)<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Cisco Nexus 3064-T and 3064-32T: 1.72 x 17.3 x 22.45 in.(4.4 x 43.9 x 57.0 cm)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Weight<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Cisco Nexus 3064-T and 3064-32T: 20.8 lb (9.5 kg)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Operating temperature<\/td>\n<td valign=\"top\">32 to 104\u00b0F (0 to 40\u00b0C)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Storage temperature<\/td>\n<td valign=\"top\">-40 to 158\u00b0F (-40 to 70\u00b0C)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Operating relative humidity<\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a010 to 85% noncondensing<\/p>\n<p>\u25cf\u00a0\u00a0Up to 5 days at maximum (85%) humidity<\/p>\n<p>\u25cf\u00a0\u00a0Recommend ASHRAE data center environment<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Storage relative humidity<\/td>\n<td valign=\"top\">5 to 95% noncondensing<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Altitude<\/td>\n<td valign=\"top\">0 to 10,000 ft (0 to 3000m)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>N3K-C3064TQ-10GT\u00a0is the Nexus 3064-T, 48 10GBase-T and 4 QSFP+ ports. The Cisco Nexus 3064-X, 3064-T, and 3064-32T Switches are high-performance, high-density Ethernet switches that are part of the Cisco Nexus 3000 Series Switches portfolio. These compact one-rack-unit (1RU) form-factor 10 Gigabit Ethernet switches provide line-rate Layer 2 and 3 switching. They run the industry-leading Cisco? NX?OS Software operating system, providing customers with comprehensive features and functions that are widely deployed globally. They support both forward and reverse airflow schemes with AC and DC power inputs. The Cisco Nexus 3064 switches are well suited for data centers that require cost-effective, power-efficient, line-rate Layer 2 and 3 top-of-rack (ToR) switches.<\/p>","protected":false},"featured_media":2589,"comment_status":"open","ping_status":"closed","template":"","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":""},"product_cat":[29,30],"product_tag":[],"class_list":{"0":"post-2586","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco","7":"product_cat-networking","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product\/2586","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/comments?post=2586"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/media\/2589"}],"wp:attachment":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/media?parent=2586"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product_cat?post=2586"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product_tag?post=2586"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}