{"id":2796,"date":"2024-09-29T15:28:52","date_gmt":"2024-09-29T07:28:52","guid":{"rendered":"https:\/\/cicserver.com\/?post_type=product&#038;p=2796"},"modified":"2024-09-29T15:28:53","modified_gmt":"2024-09-29T07:28:53","slug":"n3k-c3548p-10gx","status":"publish","type":"product","link":"https:\/\/cicserver.com\/de\/produkt-2\/n3k-c3548p-10gx\/","title":{"rendered":"N3K-C3548P-10GX"},"content":{"rendered":"<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"5\" valign=\"top\" width=\"100%\">\n<h3 align=\"center\"><strong>N3K-C3548P-10GX Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Physical<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"84%\">\u25cf\u00a0\u00a048 fixed SFP+ ports (1 or 10 Gbps)<\/p>\n<p>\u25cf\u00a0\u00a0Dual redundant hot-swappable power supplies<\/p>\n<p>\u25cf\u00a0\u00a0Four individual redundant hot-swappable fans<\/p>\n<p>\u25cf\u00a0\u00a0One 1-PPS timing port, with the RF1.0\/2.3 QuickConnect connector type*<\/p>\n<p>\u25cf\u00a0\u00a0One 10\/100\/1000-Mbps management port<\/p>\n<p>\u25cf\u00a0\u00a0One RS-232 serial console port<\/p>\n<p>\u25cf\u00a0\u00a0Two USB ports<\/p>\n<p>\u25cf\u00a0\u00a0Locator LED<\/p>\n<p>\u25cf\u00a0\u00a0Locator LED button<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Performance<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"84%\">\u25cf\u00a0\u00a0960-Gbps switching capacity<\/p>\n<p>\u25cf\u00a0\u00a0Forwarding rate of 720 mpps<\/p>\n<p>\u25cf\u00a0\u00a0Line-rate traffic throughput (both Layer 2 and 3) on all ports<\/p>\n<p>\u25cf\u00a0\u00a0Configurable MTUs of up to 9216 bytes (jumbo frames)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Typical operating power<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"84%\">\u25cf\u00a0\u00a0112W<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Maximum power<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"84%\">\u25cf\u00a0\u00a0213W<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Typical heat dissipation<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"84%\">\u25cf\u00a0\u00a0383 BTUs per hr<\/p>\n<p>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Maximum heat dissipation<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"84%\">\u25cf\u00a0\u00a0727 BTUs per hr<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" valign=\"top\">\n<p align=\"center\"><strong>Hardware Specifications<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">&nbsp;<\/td>\n<td valign=\"top\">\n<p align=\"center\"><strong>Mode<\/strong><\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\"><strong>Normal Mode<\/strong><\/td>\n<td valign=\"top\">\n<p align=\"center\"><strong>Warp Mode<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"11\" valign=\"top\">Hardware tables and scalability<\/td>\n<td valign=\"top\">Number of MAC addresses<\/td>\n<td colspan=\"2\" valign=\"top\">64,000<\/td>\n<td valign=\"top\">8000<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of IPv4 unicast routes<\/td>\n<td colspan=\"2\" valign=\"top\">24,000<\/td>\n<td valign=\"top\">4000<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of IPv4 hosts<\/td>\n<td colspan=\"2\" valign=\"top\">64,000<\/td>\n<td valign=\"top\">8000<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of IPv4 multicast routes<\/td>\n<td colspan=\"2\" valign=\"top\">8000<\/td>\n<td valign=\"top\">8000<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of VLANS<\/td>\n<td colspan=\"3\" valign=\"top\">4096<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of ACL entries<\/td>\n<td colspan=\"3\" valign=\"top\">4096<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of spanning-tree instances<\/td>\n<td colspan=\"3\" valign=\"top\">Rapid Spanning Tree Protocol (RSTP): 512<\/p>\n<p>Multiple Spanning Tree (MST) Protocol: 64<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of EtherChannels<\/td>\n<td colspan=\"3\" valign=\"top\">24<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of ports per EtherChannel<\/td>\n<td colspan=\"3\" valign=\"top\">24<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Buffer size<\/td>\n<td colspan=\"3\" valign=\"top\">6 MB shared among 16 ports; 18 MB total<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Boot flash memory<\/td>\n<td colspan=\"3\" valign=\"top\">2 GB (3524P and 3548P models)<\/p>\n<p>4 GB (3524X and 3548X models)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" valign=\"top\">Power<\/td>\n<td valign=\"top\">Number of power supplies<\/td>\n<td colspan=\"3\" valign=\"top\">2 (redundant)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Power supply types<\/td>\n<td colspan=\"3\" valign=\"top\">\u25cf\u00a0\u00a0AC (forward and reversed airflow)<\/p>\n<p>\u25cf\u00a0\u00a0DC (forward\u00a0and reversed airflow)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Input voltage<\/td>\n<td colspan=\"3\" valign=\"top\">100 to 240 VAC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Frequency<\/td>\n<td colspan=\"3\" valign=\"top\">50 to 60 Hz<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Power supply efficiency<\/td>\n<td colspan=\"3\" valign=\"top\">89 to 91% at 220V<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Cooling<\/td>\n<td colspan=\"4\" valign=\"top\">Forward and reversed airflow schemes<\/p>\n<p>\u25cf\u00a0\u00a0Forward airflow:Port-side exhaust (air enters through fan tray and power supplies and exits through ports)<\/p>\n<p>\u25cf\u00a0\u00a0Reversed airflow: Port-side intake (air enters through ports and exits through fan tray and power supplies)<\/p>\n<p>Four individual, hot-swappable fans (3+1 redundant)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\" valign=\"top\">Environment<\/td>\n<td valign=\"top\">Dimensions (height x width x depth)<\/td>\n<td colspan=\"3\" valign=\"top\">1.72 x 17.3 x 18.38 in. (4.36 x 43.9 x 46.7 cm)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Weight<\/td>\n<td colspan=\"3\" valign=\"top\">17.4 lb (7.9 kg)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Operating temperature<\/td>\n<td colspan=\"3\" valign=\"top\">32 to 104\u00b0 F (0 to 40\u00b0C)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Storage temperature<\/td>\n<td colspan=\"3\" valign=\"top\">-40 to 158\u00b0 F (-40 to 70\u00b0C)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Relative humidity (operating)<\/td>\n<td colspan=\"3\" valign=\"top\">\u25cf\u00a0\u00a010 to\u00a085% noncondensing<\/p>\n<p>\u25cf\u00a0\u00a0Up to 5 days at maximum (85%) humidity<\/p>\n<p>\u25cf\u00a0\u00a0Recommend ASHRAE\u00a0data center environment<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Relative humidity (nonoperating)<\/td>\n<td colspan=\"3\" valign=\"top\">5 to 95% noncondensing<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Altitude<\/td>\n<td colspan=\"3\" valign=\"top\">0 to 10,000 ft (0 to 3000m)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Mean time between failure (MTBF)<\/td>\n<td colspan=\"3\" valign=\"top\">317,030 hours<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>The Cisco Nexus 3548P-10GX (<a href=\"https:\/\/cicserver.com\/de\/?post_type=product&amp;p=2796&amp;preview=true\">N3K-C3548P-10GX<\/a>) is 1 rack unit (RU) switch with 48 fixed 1- and 10-Gigabit Ethernet small form-factor pluggable (SFP+) ports, 1 fixed 10\/100\/1000 management port, 1 console port, and 2 USB ports. This switch supports both port-side exhaust and port-side intake airflow schemes. It requires one AC or DC power supply for operations, but it can have a second power supply for redundancy.<\/p>","protected":false},"featured_media":2799,"comment_status":"open","ping_status":"closed","template":"","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":""},"product_cat":[29,30],"product_tag":[],"class_list":{"0":"post-2796","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco","7":"product_cat-networking","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product\/2796","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/comments?post=2796"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/media\/2799"}],"wp:attachment":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/media?parent=2796"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product_cat?post=2796"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product_tag?post=2796"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}