{"id":4051,"date":"2024-10-24T14:39:44","date_gmt":"2024-10-24T06:39:44","guid":{"rendered":"https:\/\/cicserver.com\/?post_type=product&#038;p=4051"},"modified":"2024-10-24T14:39:45","modified_gmt":"2024-10-24T06:39:45","slug":"n9k-c9316d-gx-2","status":"publish","type":"product","link":"https:\/\/cicserver.com\/de\/produkt-2\/n9k-c9316d-gx-2\/","title":{"rendered":"N9K-C9316D-GX"},"content":{"rendered":"<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"100%\">\n<h3 align=\"center\"><strong>N9K-C9316D-GX Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Ports<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">\u25cf\u00a0\u00a016 x 400\/100\/40-Gbps QSFP-DD ports<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Physical<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">\u25cf\u00a0\u00a0System memory: 16 GB NX-OS, 24 GB ACI<\/p>\n<p>\u25cf\u00a0\u00a0Solid-State Disk (SSD): 128 GB<\/p>\n<p>\u25cf\u00a0\u00a0USB: 1 port<\/p>\n<p>\u25cf\u00a0\u00a0RS-232 serial console ports: 1<\/p>\n<p>\u25cf\u00a0\u00a0Management ports: 2 (1 x 10\/100\/1000BASE-T and 1\u00a0x 1-Gbps SFP+)<\/p>\n<p>\u25cf\u00a0\u00a0Broadwell-DE CPU: 4 cores<\/p>\n<p>\u25cf\u00a0\u00a0Dimensions (H x W x D): 3.38 x 17.37 x 22.27 in. (8.59\u00a0x 44.13 x 56.58 cm)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Packet buffer<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">\u25cf\u00a0\u00a080 MB centralized buffer<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Cooling<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">\u25cf\u00a0\u00a0Fans: NXA-FAN-35CFM-PI and NXA-FAN-35CFM-PE<\/p>\n<p>\u25cf\u00a0\u00a05+1 redundancy<\/p>\n<p>\u25cf\u00a0\u00a0Port-side intake or port-side exhaust airflow direction<\/p>\n<p>\u25cf\u00a0\u00a0Hot swappable: Yes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Power<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">\u25cf\u00a0\u00a0AC:<\/p>\n<p>\u25e6\u00a0\u00a0\u00a01100 Watt (W) AC power supplies (up to 2)<\/p>\n<p>\u25e6\u00a0\u00a0\u00a01+1 redundancy<\/p>\n<p>\u25e6\u00a0\u00a0\u00a080 Plus Platinum-rated power supplies with efficiency of 90% or greater (20 to 100% load)<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Frequency: 50 to 60 Hz (AC)<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0RoHS compliance: Yes<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Hot swappable: Yes<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Port-side intake or port-side exhaust options<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Typical power: 650W (AC)<\/p>\n<p>\u25cf\u00a0\u00a0DC:<\/p>\n<p>\u25e6\u00a0\u00a0\u00a01100 Watt (W) DC power supplies (up to 2)<\/p>\n<p>\u25e6\u00a0\u00a0\u00a01+1 redundancy<\/p>\n<p>\u25e6\u00a0\u00a0\u00a080 Plus Platinum-rated power supplies with efficiency of 90% or greater (20 to 100% load)<\/p>\n<p>\u25cf\u00a0\u00a0High-voltage AC\/DC<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Power: 1200W AC, 930W DC, or 1200W HVAC\/HVDC<\/p>\n<p>\u25e6\u00a0\u00a0\u00a0Input voltage: 100 to 240V\u00a0*\u00a0AC or \u201340 to \u201372V DC (minimum and maximum), \u201348 to \u201360V DC (nominal)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Environmental<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">\u25cf\u00a0\u00a0Operating temperature: 32 to 104\u00b0F (0 to 40\u00b0C)<\/p>\n<p>\u25cf\u00a0\u00a0Nonoperating (storage) temperature: -40 to 158\u00b0F<\/p>\n<p>\u25cf\u00a0\u00a0(-40 to 70\u00b0C)<\/p>\n<p>\u25cf\u00a0\u00a0Humidity: 5 to 85% (noncondensing)<\/p>\n<p>\u25cf\u00a0\u00a0Altitude: 0 to 13,123 ft (0 to 4000m)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Maximum number of IPv4 Longest Prefix Match (LPM) routes<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">896,000<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Maximum number of IPv4 host entries<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">896,000<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Maximum number of MAC address entries<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">256,000<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Maximum number of multicast routes<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">32,000<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Number of Interior Gateway Management Protocol (IGMP) snooping groups<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">Shipping: 8000<\/p>\n<p>Maximum: 32,000<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Maximum number of Access-Control-List (ACL) entries<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">Per slice of the forwarding engine:<\/p>\n<p>\u25cf\u00a0\u00a05000 ingress<\/p>\n<p>\u25cf\u00a0\u00a02000 egress<\/p>\n<p>\u25cf\u00a0\u00a0Max: 20,000 ingress, 8000 egress<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Maximum number of VLANs<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">3967<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Number of Virtual Routing and Forwarding (VRF) instances<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">Shipping:\u00a01000<\/p>\n<p>Maximum: 16,000<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Maximum number of ECMP paths<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">64<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Maximum number of port channels<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">512<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Maximum number of links in a port channel<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">32<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Number of active SPAN sessions<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">4<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Maximum number of VLANs in Rapid per-VLAN Spanning Tree (RPVST) instances<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">3967<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Maximum number of Hot-Standby Router Protocol (HSRP) groups<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">490<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Maximum number of Multiple Spanning Tree (MST) instances<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">64<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Flow-table size used for Cisco Tetration Analytics platform<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">64,000<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Number of Network Address Translation (NAT) entries<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">1023<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Regulatory compliance<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">Products should comply with CE Markings according to directives 2004\/108\/EC and 2006\/95\/EC.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>Safety<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">\u25cf\u00a0\u00a0UL 60950-1 Second Edition<\/p>\n<p>\u25cf\u00a0\u00a0CAN\/CSA-C22.2 No. 60950-1 Second Edition<\/p>\n<p>\u25cf\u00a0\u00a0EN 60950-1 Second Edition<\/p>\n<p>\u25cf\u00a0\u00a0IEC 60950-1 Second Edition<\/p>\n<p>\u25cf\u00a0\u00a0AS\/NZS 60950-1<\/p>\n<p>\u25cf\u00a0\u00a0GB4943<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>EMC: Emissions<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">\u25cf\u00a0\u00a047CFR Part 15 (CFR 47) Class A<\/p>\n<p>\u25cf\u00a0\u00a0AS\/NZS CISPR22 Class A<\/p>\n<p>\u25cf\u00a0\u00a0CISPR22 Class A<\/p>\n<p>\u25cf\u00a0\u00a0EN55022 Class A<\/p>\n<p>\u25cf\u00a0\u00a0ICES003 Class A<\/p>\n<p>\u25cf\u00a0\u00a0VCCI Class A<\/p>\n<p>\u25cf\u00a0\u00a0EN61000-3-2<\/p>\n<p>\u25cf\u00a0\u00a0EN61000-3-3<\/p>\n<p>\u25cf\u00a0\u00a0KN22 Class A<\/p>\n<p>\u25cf\u00a0\u00a0CNS13438 Class A<\/p>\n<p>Note:\u00a0Cisco Nexus N9K-C9364C passes EMC Radiated Emissions standards in all configurations, with the only exception being if more than 40 pluggable optics of Cisco part number 10-3142-02 (or 10-3142-01) are used.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>EMC: Immunity<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">\u25cf\u00a0\u00a0EN55024<\/p>\n<p>\u25cf\u00a0\u00a0CISPR24<\/p>\n<p>\u25cf\u00a0\u00a0EN300386<\/p>\n<p>\u25cf\u00a0\u00a0KN 61000-4 series<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"34%\"><strong>RoHS<\/strong><\/td>\n<td valign=\"top\" width=\"65%\">The product is RoHS-6 compliant with exceptions for leaded Ball Grid-Array (BGA) balls and lead<br \/>\npress-fit\u00a0connectors.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>N9K-C9316D-GX\u00a0is the Cisco Nexus 9316D Spine switch with 16p 400\/100G QSFP-DD. Based on Cisco\u00ae Cloud Scale technology, the Cisco Nexus\u00ae 9300-GX switches are the next generation of fixed Cisco Nexus 9000 Series Switches. The platform introduces a fully backward-compatible 400G optical interface Quad Small Form-Factor Pluggable \u2013 Double Density (QSFP-DD) to transparently migrate existing data center fabrics from 40-Gbps and 100-Gbps speeds to 400 Gbps. The platform provides investment protection for customers, delivering highly flexible layer 2 and layer 3 scalability, and performance to meet the changing needs of virtualized data centers and automated cloud environments.<\/p>","protected":false},"featured_media":4054,"comment_status":"open","ping_status":"closed","template":"","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":""},"product_cat":[29,30],"product_tag":[41],"class_list":{"0":"post-4051","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco","7":"product_cat-networking","8":"product_tag-nexus-9000","10":"first","11":"instock","12":"shipping-taxable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product\/4051","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/comments?post=4051"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/media\/4054"}],"wp:attachment":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/media?parent=4051"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product_cat?post=4051"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product_tag?post=4051"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}