{"id":4139,"date":"2024-10-24T15:21:43","date_gmt":"2024-10-24T07:21:43","guid":{"rendered":"https:\/\/cicserver.com\/?post_type=product&#038;p=4139"},"modified":"2024-10-24T15:21:44","modified_gmt":"2024-10-24T07:21:44","slug":"ie-2000u-16tc-gp","status":"publish","type":"product","link":"https:\/\/cicserver.com\/de\/produkt-2\/ie-2000u-16tc-gp\/","title":{"rendered":"IE-2000U-16TC-GP"},"content":{"rendered":"<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"568\">\n<h3 align=\"center\"><strong>IE-2000U-16TC-GP Specification<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>Total Ports<\/strong><\/td>\n<td valign=\"top\" width=\"382\">18<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>RJ45 Ports<\/strong><\/td>\n<td valign=\"top\" width=\"382\">16 FE<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>Combo Ports<\/strong><\/td>\n<td valign=\"top\" width=\"382\">2 GE<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>Software<\/strong><\/td>\n<td valign=\"top\" width=\"382\">LAN Base<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>IEEE 1588<\/strong><\/td>\n<td valign=\"top\" width=\"382\">Yes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>PRP<\/strong><\/td>\n<td valign=\"top\" width=\"382\">Yes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>PoE<\/strong><\/td>\n<td valign=\"top\" width=\"382\">Yes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>Hardware<\/strong><\/td>\n<td valign=\"top\" width=\"382\">\u25cf\u00a0\u00a0256 MB DRAM with ECC memory<\/p>\n<p>\u25cf\u00a0\u00a01 GB removable SD flash memory card (CG swap drive) \u2013 (128MB space available)<\/p>\n<p>\u25cf\u00a0\u00a0Mini-USB connector<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>Alarm<\/strong><\/td>\n<td valign=\"top\" width=\"382\">\u25cf\u00a0\u00a0Alarm I\/O: two alarm inputs to detect dry contact open or closed, one alarm output relay. 48 VDC, 0.5A max<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"186\"><strong>Power Supply<\/strong><\/td>\n<td valign=\"top\" width=\"382\">\u25cf\u00a0\u00a0Redundant DC input voltage with operating range: 12-48 VDC Nominal, 9.6-60 VDC Maximum<\/p>\n<p>\u25cf\u00a0\u00a0Maximum DC input current: 0.5A at 48 VDC, 1A at 24 VDC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Substation Compliance<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0IEC 61850-3<\/p>\n<p>\u25cf\u00a0\u00a0IEEE1613<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Hazardous Location<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0ANSI\/ISA 12.12.01 (Class 1, Div 2 A-D) (requires cabinet enclosure)<\/p>\n<p>\u25cf\u00a0\u00a0UL\/CSA 60079-0, -15 (Class 1, Zone 2, group II gases, requires cabinet enclosure)<\/p>\n<p>\u25cf\u00a0\u00a0EN 60079-0, -15 ATEX certification (Class I, Zone 2, Group II gases, requires cabinet enclosure)<\/p>\n<p>\u25cf\u00a0\u00a0IEC 60079-0, -15 (Class I Zone 2, Group II gases, requires cabinet enclosure)<\/p>\n<p>\u25cf\u00a0\u00a0CSA 213<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Industrial Control Safety<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0UL508<\/p>\n<p>\u25cf\u00a0\u00a0CSA C22.2 No. 142<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>EMC Interface Immunity<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0EN 55024 (CISPR 24)<\/p>\n<p>\u25cf\u00a0\u00a0AS\/NZS CISPR 24<\/p>\n<p>\u25cf\u00a0\u00a0KN 24<\/p>\n<p>\u25cf\u00a0\u00a0IEC61000-4-2 (Criteria A &#8211; Class 2)<\/p>\n<p>\u25cf\u00a0\u00a0IEC61000-4-3\/ENV50204 (Criteria A)<\/p>\n<p>\u25cf\u00a0\u00a0IEC61000-4-4 (Criteria A\/Criteria B)<\/p>\n<p>\u25cf\u00a0\u00a0IEC61000-4-5 (Criteria B)<\/p>\n<p>\u25cf\u00a0\u00a0IEC61000-4-6 (Criteria A)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Standard Electromagnetic Emissions Certifications<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0FCC Part 15 Class A<\/p>\n<p>\u25cf\u00a0\u00a0EN 55022 Class A (CISPR22 Class A)<\/p>\n<p>\u25cf\u00a0\u00a0ICES-003 Class A<\/p>\n<p>\u25cf\u00a0\u00a0EN 300 386<\/p>\n<p>\u25cf\u00a0\u00a0VCCI Class A<\/p>\n<p>\u25cf\u00a0\u00a0AS\/NZS CISPR22 Class A<\/p>\n<p>\u25cf\u00a0\u00a0CNS 13438 Class A<\/p>\n<p>\u25cf\u00a0\u00a0KN 22 Class A CE Marking<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Standard Safety Certifications<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0UL 60950-1<\/p>\n<p>\u25cf\u00a0\u00a0CSA 60950-1<\/p>\n<p>\u25cf\u00a0\u00a0EN 60950-1<\/p>\n<p>\u25cf\u00a0\u00a0IEC 60950-1, CB report and certificate with all national differences<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Operating Environment<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Operating Temperature: -40C to +75C<\/p>\n<p>\u25cf\u00a0\u00a0-40C to +70C (Vented Enclosure \u2013 40 LFM Air Flow)<\/p>\n<p>\u25cf\u00a0\u00a0-40C to +60C (Sealed Enclosure \u2013 0 LFM Air Flow)<\/p>\n<p>\u25cf\u00a0\u00a0-34C to +75C (Fan or Blower equipped Enclosure \u2013 200 LFM Air Flow)<\/p>\n<p>\u25cf\u00a0\u00a0-40 to +85C (IEC 60068-2-2 Environmental Type testing &#8211; 100 hours)<\/p>\n<p>\u25cf\u00a0\u00a0Operating altitude: -60 m (-200 ft) to 3,000 m (10,000 ft), de-rate maximum operating temperature per IEEE 1613-2009:<\/p>\n<p>\u25cf\u00a0\u00a0Relative humidity: 5% to 95% non-condensing<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Storage Environment<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Temperature: -50\u00ba C to +85\u00ba C<\/p>\n<p>\u25cf\u00a0\u00a0Altitude: 15,100 ft (4600 m)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Warranty<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0Five-year limited warranty on all IE-2000U HW PIDs<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong>Protection Class Code<\/strong><\/td>\n<td valign=\"top\">\u25cf\u00a0\u00a0IP30 per EN60529<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>IE-2000U-16TC-GP is a Cisco IE 2000U series switch, providing 16 x 10\/100,2 T\/SFP GE ports with 1588, PoE. the Cisco Industrial Ethernet (IE) 2000U Switches are compact switches for the harsh, rugged environments often found in the energy and utility industries. IE 2000U switches support the communications needs of the utility- and customer-owned energy-delivery infrastructure across distributed generation, transmission, and distribution sectors. This infrastructure includes substation applications supporting electrical transmission and distribution, renewable generation, oil and gas, water, distributed generation, cogeneration, and trackside operations.<\/p>","protected":false},"featured_media":4142,"comment_status":"open","ping_status":"closed","template":"","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":""},"product_cat":[29,30],"product_tag":[44],"class_list":{"0":"post-4139","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco","7":"product_cat-networking","8":"product_tag-ie2000","10":"first","11":"instock","12":"shipping-taxable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product\/4139","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/comments?post=4139"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/media\/4142"}],"wp:attachment":[{"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/media?parent=4139"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product_cat?post=4139"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cicserver.com\/de\/wp-json\/wp\/v2\/product_tag?post=4139"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}