N3K-C3548P-10GX

The Cisco Nexus 3548P-10GX (N3K-C3548P-10GX) is 1 rack unit (RU) switch with 48 fixed 1- and 10-Gigabit Ethernet small form-factor pluggable (SFP+) ports, 1 fixed 10/100/1000 management port, 1 console port, and 2 USB ports. This switch supports both port-side exhaust and port-side intake airflow schemes. It requires one AC or DC power supply for operations, but it can have a second power supply for redundancy.

N3K-C3548P-10GX Specification

Physical ●  48 fixed SFP+ ports (1 or 10 Gbps)

●  Dual redundant hot-swappable power supplies

●  Four individual redundant hot-swappable fans

●  One 1-PPS timing port, with the RF1.0/2.3 QuickConnect connector type*

●  One 10/100/1000-Mbps management port

●  One RS-232 serial console port

●  Two USB ports

●  Locator LED

●  Locator LED button

Performance ●  960-Gbps switching capacity

●  Forwarding rate of 720 mpps

●  Line-rate traffic throughput (both Layer 2 and 3) on all ports

●  Configurable MTUs of up to 9216 bytes (jumbo frames)

Typical operating power ●  112W
Maximum power ●  213W
Typical heat dissipation ●  383 BTUs per hr

 

Maximum heat dissipation ●  727 BTUs per hr

Hardware Specifications

 

Mode

Normal Mode

Warp Mode

Hardware tables and scalability Number of MAC addresses 64,000 8000
Number of IPv4 unicast routes 24,000 4000
Number of IPv4 hosts 64,000 8000
Number of IPv4 multicast routes 8000 8000
Number of VLANS 4096
Number of ACL entries 4096
Number of spanning-tree instances Rapid Spanning Tree Protocol (RSTP): 512

Multiple Spanning Tree (MST) Protocol: 64

Number of EtherChannels 24
Number of ports per EtherChannel 24
Buffer size 6 MB shared among 16 ports; 18 MB total
Boot flash memory 2 GB (3524P and 3548P models)

4 GB (3524X and 3548X models)

Power Number of power supplies 2 (redundant)
Power supply types ●  AC (forward and reversed airflow)

●  DC (forward and reversed airflow)

Input voltage 100 to 240 VAC
Frequency 50 to 60 Hz
Power supply efficiency 89 to 91% at 220V
Cooling Forward and reversed airflow schemes

●  Forward airflow:Port-side exhaust (air enters through fan tray and power supplies and exits through ports)

●  Reversed airflow: Port-side intake (air enters through ports and exits through fan tray and power supplies)

Four individual, hot-swappable fans (3+1 redundant)

Environment Dimensions (height x width x depth) 1.72 x 17.3 x 18.38 in. (4.36 x 43.9 x 46.7 cm)
Weight 17.4 lb (7.9 kg)
Operating temperature 32 to 104° F (0 to 40°C)
Storage temperature -40 to 158° F (-40 to 70°C)
Relative humidity (operating) ●  10 to 85% noncondensing

●  Up to 5 days at maximum (85%) humidity

●  Recommend ASHRAE data center environment

Relative humidity (nonoperating) 5 to 95% noncondensing
Altitude 0 to 10,000 ft (0 to 3000m)
Mean time between failure (MTBF) 317,030 hours